ACCULOAD 发油控制器说明书


Electronic Preset Delivery System

AccuLoad II
Installation
Issue/Rev. 0.8 (8/95) Bulletin MN06037

TM

The Most Trusted Name In Measurement

> Section 1 - General

J1

J2

J4

Figure 2 InterFace Board
MN06037 Issue/Rev. 0.8 (8/95) 7

J5

J3, J6, J7 and J8

Section 1 - General

Note: Dimensions - Inches to the nearest tenth (millimeteres to the nearest whole mm), each independently dimensioned from respective engineering drawings.

Figure 4 AccuLoad II NEMA IV Dimensions
MN06037 Issue/Rev. 0.8 (8/95) 9

MN06037 Issue/Rev. 0.8 (8/95)

Figure 6 Terminal Block Layout - Graphics Panel

Section I - General

Notes: 1. If security switches are not used, these terminals should be tied to the incoming power line. 2. Jumper Positions shown for 120 or 240 operation. 3. Preset Position #1 - Red - DC connections 1 through 24, 43, and 44 - AC connections 73 and 74, 80 through 105 4. Preset Position #2 - Yellow - DC connections 45 and 46, 49 through 72 - AC connections 75 and 76, 106 through 131 5. Common to both Preset Positions - White - DC connections 25 through 42 - AC connections 77 through 79, 132 through 134

11

Section 1 - General

Printer Output Jumpers

1. After assembling QOPV kit to AccuLoad II, connect numbered wires from header (part of QOPV Board) to corresponding terminal points on AccuLoad II I/O Board.

Figure 16 Quad OPV
MN06037 Issue/Rev. 0.8 (8/95) 21

Section 1 - General

for Remote Start on Position #2 for Remote Start on Position #1

1. Locate jumper locations J1 and J2 on the keypad board. 2. Mount shunt plugs as indicated above for both J1 and J2. (J1 - Preset Position #1 and J2 Preset Position #2). 3. Wire remote start input to ac terminal 103 (Preset Position #1) and ac terminal 110 (Preset Position #2). 4. Program both Preset Positions for Remote Stop under Permissive Sense #1 in the 800 directory of the program.

Figure 17 Remote Start
22 MN06037 Issue/Rev. 0.8 (8/95)

Section 1 - General

1. Locate jumper locations J8 and J9 on the computer board. 2. Mount shunt plugs as indicated above in lower two positions of both J8 and J9. (J8 - Preset Position #2 and J9 - Preset Position #1) 3. Wire remote stop input to ac terminal 104 ( Preset Position #1) and ac terminal 111 (Preset Position #2). 4. Program both Preset Positions for Remote Stop under Permissive Sense #2 in the 800 directory of the program.

Figure 18 Remote Stop
MN06037 Issue/Rev. 0.8 (8/95) 23

Section 4 - AccuLoad II-SEQ

A

D External Permissives

C

B

AccuLoad II Preset Position #2
Input #6
75

Voltage Sense Voltage Sense Voltage Sense

76

Input #4
110

Input #5
111

112

114

118

N.C. N.O.

Stop Relay
115

Upstream
116

210 Valve Upstream Sol. Downstream Sol.

Downstream
117

N.C. AIJ-1 Sol. AIJ-2 Sol. AIJ-3 Sol. AIJ-4 Sol.
R1 R2

Relay #1
124 125

Relay #2
126 127

Relay #3
128 129

Relay #4
130 131

Pump
119 120

Relay #5
121 122 123 108

Input #3 Input #1
106

Voltage Sense Voltage Sense Voltage Sense
109

N.C.

Input #2
107

113

N.C. 1 2 N.C. N.C. N.C. +4 to 20 -4 to 20 +4 to 20 -4 to 20 +24 Vdc 24V Return 4-20 mA Input 1 4-20 mA Input 2 Densitometer Load Printer

Temperature Probe (100 ?) Red Red Black Black
62 63 58 64 65 66 54 59 60 61 57

Shield -12V Meter Power Channel A

71

2 5 6 3 4 1 PPS Transmitter A N.C. N.C.

55 49

72 70 68

50 52

Channel B
53 51 56 67

69

Common
45 46

Pressure Xducer Transducer Power B

Note: 1. If external relay permissives are used in series with AccuLoad II relays, an RC network must be placed in parallel with the permissive to prevent a false turn on of the AccuLoad II relays. Recommended RC network = 0.1 uF capacitor and a 680 ohm resistor (Electrocube part number RG 2031-11). 2. Any device shown outside of the AccuLoad II housing is to be supplied by the customer. 3. Dotted connection lines indicate options. 4. For other meter transmitter connections, see Figure 33 for specific connections.

Figure 38 AccuLoad II Wiring Schematic (Preset Position 2)

MN06037 Issue/Rev. 0.8 (8/95)

53

Section 5 - Related Publications
The following literature can be obtained from FMC Technologies Measurements Solutions, Inc. Literature Fulfillment at johno@gohrs.com or online at www.fmctechnologies.com/measurementsolutions. When requesting literature from Literature Fulfillment, please reference the appropriate brochure number and title.

Valves
Model 210 - Specifications ................................................................................................................ Bulletin SS03009 Model 210 - Installation/Operation ...................................................................................................... Bulletin MN03010 Model 215 - Specifications ................................................................................................................ Bulletin SS03010 Model 215 - Installation/Operation ...................................................................................................... Bulletin MN03006 Model 215 - Service .......................................................................................................................... Bulletin MN03007 Parts List ................................................................................................................................ Consult Parts Operation

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

Headquarters: 1803 Gears Road, Houston, TX 77067 USA, Phone: 281/260-2190, Fax: 281/260-2191

Gas Measurement Products: Erie, PA USA Phone 814/898-5000 Thetford, England Phone (44) 1842-82-2900 Kongsberg, Norway Phone (47) 32/286-700 Buenos Aires, Argentina Phone 54 (11) 4312-4736 Integrated Measurement Systems: Corpus Christi, TX USA Phone 361/289-3400 Kongsberg, Norway Phone (47) 32/286-700 San Juan, Puerto Rico Phone 787/274-3760 United Arab Emirates, Dubai Phone 971 +4/331-3646

Liquid Measurement Products: Erie, PA USA Phone 814/898-5000 Los Angeles, CA USA Phone 661/702-8660 Slough, England Phone (44) 1753-57-1515 Ellerbek, Germany Phone (49) 4101-3040 Barcelona, Spain Phone (34) 93/201-0989 Moscow, Russia Phone (7) 495/564-8705 Melbourne, Australia Phone (61) 3/9807-2818

Beijing, China Phone (86) 10/6500-2251 Singapore Phone (65) 6861-3011 Chennai, India Phone (91) 44/450-4400

Visit our website at www.fmctechnologies.com
Printed in U.S.A. ? 8/95 FMC Technologies Measurement Solutions, Inc. All rights reserved. MN06037 Issue/Rev. 0.8 (8/95)