Total Sulfur/Chlorine Analyzer Total Organic Halogen Analyzer Total Nitrogen Detector Option

Model TOX-100

ISO 9002 JQA-0764

Advanced database software and the reputed coulometry methods allow measurement of chlorine and sulfur content in solid, liquid and gaseous samples down to the ppm level -- to be fully utilized at various plants. (Confirms to ASTM D3120, 3246, 3961, 5808, JIS K2541)

1 System Con?guration Accommodating
the Speci?c Purpose of Use
The system can be configured exactly as required by using various options according to the particular sample.

2 Outstanding Ease of Operation and
Improved Functions Using W indows ?
The system can be operated easily and simply. All measurement conditions are stored in the database, enabling the measurement of samples to be performed simply by selecting the optimum conditions.

Model TOX-100 Standard Set

Options(Accessories)

Personal Computer

Liquid samples CRI-100H
(Constant Rate Injector)

TOX-100 Main Unit Solid and liquid samples ABC
(Automatic Boat Controller)

Gaseous samples GI-100
(Gas Injector)

3 High-Speed Analysis Through the Use
of Automatic Boat Controller ( ABC)
Operation is started simply by placing a sample in the sample boat. Analysis is performed automatically in about 5-10 minutes. The standard system enables sample analysis to be performed with outstanding reproducibility. Since the sample inlet box is provided with a cooling function (electronic cooling), the sample boat can be cooled in a short time.

Options (Chlorine/Sulfur Titration Cell) Chlorine Titration Cell Unit Sulfur Titration Cell Unit
AUTOMATION Liquid samples ASC-150L
(Liquid Auto Sampler)

Samples
Solid and Liquid Liquid Gas

System Configulation
Model TOX-100 Standard Set Model TOX-100 Std. Set + CRI-100H Model TOX-100 Std. Set + GI-100

Liquid Automation Model TOX-100 Std. Set +ABC + ASC-150L Solid Automation Model TOX-100 Std. Set + ASC-120S

AUTOMATION Solid samples ASC-120S
(Solid Auto Sampler)

ABC SPECIFICATIONS 3 Points + End Point + Cooling Point Stop Points Boat Cooling Peltier Cooler Power Supply AC 100/115/230/240 V, 50/60 Hz, 40 VA Approx. 440 (W) 250 (D) 180 (H) kg Dimensions Approx. 10 kg Weight

Measurement Principle

Chlorine Analysis burned
Samples are burned in an Argon/Oxygen atmosphere. The resulting chloride is lead into a titration cell where it is automatically titrated by silver ions generated coulometrically. The amount of chlorine is then calculated from the quantity of electricity required for the titration.

Working Electrode/ Counter Electrode Sensor Electrode Reference Electrode Cell Unit Control Unit

O2

Ar/O2

Mass Flow Sensor

Reaction Unit

Ryrolysis Tube

Sample Inlet (liquid, solid) Cooling Unit

Sulfur Analysis burned
Samples are burned in an Argon/Oxygen atmosphere. The resulting sulfur dioxide is lead into a titration cell where it is automatically titrated by triiodide ions generated coulometrically. The amount of sulfur is then calculated from the quantity of electricity required for the titration.

Safety Cover

Sample Boat Heater 2 Stirrer Dehydrating Tube Heater 1

TOX-100 Main Unit

Automatic Boat Controller

Applications
Chlorine Analysis
Sample Name Lubricating Oil Kerosene Crude Oil Rubber Carbon Fiber Epoxy Resin Polycarbonate Resin Photoresist Aluminum Foil Waste Oil Cement
No. Sample Size ( mg ) Measurements Measured Value (ppm) ) of 30 3 34

Sulfur Analysis
RSD(%) 4 3 3 4 3 5 3 2 6 3 3 4 3 3 4 3 5 3 2 6 3 3 Sample Name Lubricating Oil Heavy Oil Engine Oil Polypropylene Surface Activator Rubber Manganese Oxide Zinc Oxide Lanolin Fish Oil Soil
No. of Sample Size (mg ) Measurements Measured Value (ppm) 3 3 0.76%

RSD(%) 3 3 4 5 0.5 1 7 0.7 5 4 6

30 30 20 20 10 30 30 20 10 10

3 3 3 3 3 3 3 3 3 3

31 4.0 210 193 890 7.9 7.2 5.5 390 460

10 5 30 5 15 30 30 30 20 5

3 3 3 3 3 3 3 3 3 3

1.2% 0.41% 2.0 883 0.55% 37 14 39 180 369

Typical Applications of Hydrocarbons
Petroleum Products Liquified Petroleum Gas Naphtha Gasoline(lead-free) Kerosene Gas Oil Fuel Oil Crude Oil Paraffines Olefins Aromatics Alcohols Aldehydes Ketones Ethers Esters

Carboxylic Acids

Total Sulfur/Chlorine Analyzer Model TOX-100 Standard Set TOX-100 Main Unit Automatic Boat Controller PC Chlorine or SulfurTitration Unit (Option)

Options
Constant Rate Injector Model CRI-100H (CRI Mode) Gas Injector Model GI-100
The system is used for the analysis of chlorine and sulfur in gaseous samples.

SPECIFICATIONS Applicable Sample Sample Size Gas Requirements Power Supply Dimensions Weight Gaseous Sample Standard Sample: Max. 20 Gas Sample: Max. 10 m (Gastight Microsyringe) (Gastight Microsyringe)

Argon (purity: 99.98% or more, 290-490 kPa) AC100/115/230/240V, 50/60Hz, 30VA Approx. 120(W) x 250(D) x 235(H) mm Approx. 4

Liquid samples are injected into the pyrolysis tube at a constant rate using a microsyringe. The measurement can be performed with greater accuracy since differences between the liquid properties of the sample can be controlled with the injection rate.
SPECIFICATIONS Syringe Injection Rate Injection Volume Power Supply Dimensions Weight Approx. 6 /sec. Sample injection rate is normally 1.0 50 0.4 100 2.0 /sec 250 (Gastight Microsyringe)

Humidifier (POX Sparger) Model POX-100
The humidifier provides humidity for the carrier gas when analyzing inorganic chlorine compound to facilitate conversion to hydrogen chloride.

Max. 250 AC 100/115/230/240V 50/60Hz 40VA
mm

Solid Auto Sampler Model ASC-120S
Up to 20 sample boats can be set on the table to have them analyzed automatically. Due to installation of ABC, the combustion program can be set separately for each sample.

Liquid Auto Sampler Model ASC-150L

SPECIFICATIONS Sample Sample Size Sample Boat Solids/ Viscous Liquid Samples Less than 30 20 Places Quarts Sample Boat or Ceramic Sample Boat Automatic Boat Controller (ABC)

To be used in combination with the Auto Boat Controller (ABC), Liquid Auto Sampler Model ASC-150L is an autosampler in which liquid samples (max. 50 bottles) are injected automatically.
SPECIFICATIONS Sample Syringe Precision Injection Rate Fill Rate Sample Vial Rince Vial Sample Inj. Times Multi Inj. Times Rincing Function Aqueous and/or Nonaqueous Samples Hamilton 25 , 50 , 100 Standard attachment; 50 Within 1%/ Full scale Low; 0.4-2.0 /sec High; 10-50 /sec 2, 5, 10, 20 /sec 5 / 50 places 28 / 1 or 2 places 1-30 times / 1 vial 1-10 times / 1 vial Initial Rince ; 0-5 times Sample Rince ; 0-5 times Normal Rince ; 0-5 times Flush, Spike AC 100/115/230/240 V, 50/60 Hz, 60VA Approx. 460 ( W ) x 320 ( D ) x 450( H ) Approx. 16 /Gastight Microsyringe

Sample Introduction

ABC SPECIFICATIONS 3 Points + End Point + Cooling Point Stop Points Boat Cooling Peltier Cooler Power Supply AC 100/115/230/240V, 50/60 Hz, 60VA (H ) Approx. 440 ( W) 360 ( D) Dimensions Approx. 20 Weight

Injection Mode Power Supply Dimensions Weight

The Total Nitrogen Detector Option enables measurement Total of total nitrogen when connected to the TOX-100 system, thus making it possible to measure microscopic quantities of total nitrogen in resins and petrochemical products.

Measurement Principle
O2 O2 Ar/O2

The sample is introduced into the combustion tube packed with oxidative catalyst using Argon carrier gas. High temperature oxidation (800-900°C) occurs here and all chemically bound nitrogen is converted to nitric oxide (NO). NO then passes through the chemiluminescence detector where it is mixed with ozone to form excited nitrogen dioxide (NO 2 *).

Mass Flow Sensor Chemiluminescence Detector Cell Unit Control Unit

Pyrolysis Tube Ozone Scrubber

Sample Inlet (liquid, solid) Cooling Unit Safety Cover

Sample Boat

Rapid decay of the NO2* produces light in the 5902,900 nanometer range. This light is detected and amplified by a photomultiplier tube. The result is calculated from the resulting signal and printed out in ppm or %.

Ozone Generator Stirrer Vacuum Pump

Heater 2

Heater 1

TOX-100 Main Unit

Automatic Boat Controller

Total Nitrogen Detector Option

Applications

Sample Name Polypropylene Film Polyethylene Polycarbonate Polystyrene Epoxy Resin Wax Pulp Rice

Sample Size (mg) 10 7 10 30 20 10 30 3 3

No. of Measurements

Measured Value (ppm) 85 290 33 2.2 12 10 14.5 0.30 % 0.64 %

RSD(%) 3 2 2 6 4 3 3 1.8 3.7

5 3 3 3 3 3 3 3 3

Standard Specifications
Model
Method Samples Furnace Temperature Catalyst Measuring Range Sample Size Reproducibility (by standard sample)

Total Nitrogen Detector Option for Model TOX-100 (TN-Option)
Catalytic oxidative pyrolysis/chemiluminescence Liquids, solids and gaseous samples Max. 1,100 C(By TOX-100) Platinum Catalyst 0.5 - 5,000 ppm Liquid : 50 or less, Solid : 30mg or less, Gas Sample Size 20 20 20 40 : 10 or less Standard Sample : Pyridine/Toluene Solution
O

Concentration 500 100 10 1

RSD (%) 3 3 5 6

Measurement Time Data Processing Function Display Function Printing Function Keyboard Interface Analog Output Gas Requirements

3 - 10 min. Using a personal computer (TOX-100) Displayed on a PC-CRT (TOX-100)

Printout using an external printer PC full keyboard (TOX-100)

Balance Input (RS232C) : 1 channel (TOX-100) DC 0 - 1 V full scale Argon (purity : 99.98% or more, 200 - 390 kPa) Oxygen (purity : 99.7% or more, 200 - 390 kPa) TOX-100 Main Unit : AC 100/115/230/240V, 1,000VA TOX-100 ABC : AC 100/115/230/240V, 40VA TN-Option : AC 100/115/230/240V, 500VA TOX-100 Main Unit : Approx. 550 (W) x 360 (D) x 430 (H) mm, Approx. 36 kg TOX-100ABC : Approx. 440 (W) x 250 (D) x 180 (H) mm, Approx. 10 kg TN-Option : Approx. 260 (W) x 400 (D) x 435 (H) mm, Approx. 17 kg

Power Supply

Dimensions and Weight

Personal Computer (System Requirements to Run TN-Option System Program) Processor Memory HD Drive Display Pentium ? 133MHz or higher 32MB or higher Requires at least 100MB of available disk space 3.5-inch floppy disk drive Display resolution of at least 640 x 480

1. The optional Gas Injector is needed for measuring gaseous samples. 2. When used with the optional Constant Rate Injector, more quantity of liquid sample (max. 100 ) could be injected. 3. External printer (Windows?95/98) is needed for printing reports. 4. 1 kg/cm2 = 98.066 kPa 5. Available only with the English-language version of Windows?95/98. The specifications for the personal computer are minimum requirements to run the TN-Option System Program. Company and product names contained herein are the trademarks or registered trademarks of the companies concerned.

600

440

550 260 650 500

Windows 95 95/98 operating system and data base management... ...these excellent software applications offer basic through the latest function.

TOX-100 System Program
By connecting the TOX-100 system with a personal computer, the TOX-100 System Program gives the PC side control of such operations as switching the heater on and off, starting and stopping titration and setting titration parameters. Moreover, the program is 32-bit compatible, and with Microsoft Windows?95/98 and Microsoft?Jet data base management software, the following functions are provided:

User Friendly Software

Data Search Function

Method File

Data Base Query
The system uses Microsoft ? Jet software as its data base manager.Tiltration data (Analysis Parameters.) and measurement data (blank data, calibration data, sample data, etc.) are all stored in the data base. To make effective use of the data base, the TOX-100 system program employs multiple keywords to provide data search function. Calibration, samples and other data registered in the data base can be quickly searched for. In addition, queried data is stored in CSV format and can be used with other application software, allowing free handling of data.

Measurement of samples can be facilitated by inputting a list of samples into the Method File in advance. Open the Method File and select samples to start running the measurement process. Template of the Method File is included in the package as a standard.

Method File DB Query Open Data Base QC Program
TOX-100 System Program QC Package(Option)

Easy Access to LIMS(Custom Made)

Export Data To LIMS
Sending the valuable analysis data to LIMS is a relatively simple task. The TOX-100 system program is designed to adapt flexibly to the networks.

Compatibility with Other Application Software

Open Data Base
Export Data To LIMS
Custom Made

Quality Control Software (Option)

QC Program
Two system diagnostic programs are available for system diagnostics (cell check, system check). In addition, QC programs fully compatible with DIN and EPA(ICR) methods are included. TOX-100 System including QC Package is available as an option.

Special Features of the TOX-100 System Program

By making data base data open, commercial application software to create original, customized analysis systems and reports can be used. Customize the data and analysis by producing graphs, tables and char ts on spread sheet (e.g. Excel, Lotus) and compiling the report on your favorite word processing software (e.g. Microsoft Word).

Cell Check

Daily Check

TOX-100 QC Program
System Diagnostic Function

System Check

Reproducibility Check

Report Format
Three types of report formats are available as standard: Summary Report (Sample Average Report), the Customized Report and Crystal Report ?. In addition, the open data base permits the original reports to be created.

Compile Various Data into a Single Report

Compile the Report in a Customized Format

Summary Report (Sample Average Report )
The analsis parameters, calibration data and sample data can be compiled in a single report. Measurement average values, standard deviations and relative standard deviations are reported based on the results of the sample measurements.

Customized Report
The customized report can be prepared by selecting report header, comments and other necessary report items.

Print Out the Searched Data

Crystal Report

?

Data searched from the data base can be printed out on the Crystal Report ?.

Utilize Commercial Application Software

Original Report
Thanks to the open data base design, an original report is obtainable through original programming using the commercial application software such as Excel and Access.

Simple, quick and high precision measurement of organic halogens... ...in river and ground waters and various types of rising drainage.

System Merits
The model TOX-100 is the completely overhauled successor to the previous TOX-10 system. It is designed to measure and analyze newly regenerated TOX (AOX), POX and EOX. Employing our original coulometric and activated carbon (AC) technologies officially certified internationally by the EPA, ASTM, ISO and DIN, the system measures trace amount of organic halogen in water with high sensitivity and accuracy.

The TOX-100 is equipped with all necessary systems for measuring TOX. It can measure TOX (AOX) in conjunction with the TXA-03 Adsorption Module, POX (purgeable organic halogens) with the POX100 POX Sparger and EOX (extractable organic halogens) with the CRI-100H Constant Rate Injector.

WASHING
Nitrate

COMBUSTION

ADSORPTION
10 200

Total Organic Halogen Analyzer Model TOX-100 Standard Set TOX-100 Main Unit Automatic Boat Controller PC Chlorine Titration Cell Unit Option

Adsorption and Washing
A sample of 10-200 is passed at a constant rate of approximately 3 /min. through two columns filled with activated carbon (40 x 2), causing AOX adsorption by the activated carbon. The adsorbed columns are moved to a washing channel, rinsed with a nitrate solution (approx. 0.8%, 2 ), and the partially adsorbed inorganic halogen compound is removed.

Combustion
The activated carbon adsorbing the AOX is extruded into the sample boat, and the boat inserted into the pyrolysis tube. The AOX together with activated carbon is burned in an Oxygen stream and converted into hydrogen halide.

Titration
The generated hydrogen halide is guided into a titration cell where automatic titration is effected by coulometrically-generated silver ions.

From the quantity of electricity determined by titration, the halogen amount is calculated based on Faraday’s law and displayed in a chlorine-equivalent value.

Sample Name
River Water A River Water B River Water C Sea Water A Sea Water B Distilled Water Factory Wastewater A Factory Wastewater B Factory Wastewater C

Sample Volume(
50 50 50 40 50 100 50 20 20

No.of Measurement Measured Value
3 3 3 3 3 3 3 3 3 21 78 40 49 64 3.8

RSD
9 4 4 4 8 10 2 2 0.8

1.5 18 54

Diluted by 100 times with distilled water.

Model TXA-03 Adsorption Module
After setting the activated carbon columns, the unit automatically performs the AOX adsorption and the nitrate washing.
SPECIFICATIONS
Operating Method No. of Channels Sample Size Automatic Burette Method 3 channels 2 : Adsorption, 1 : Washing Burette1,2 10 n Washing Power Supply Dimensions Weight Approx. 330 W Approx. 8 2 n 5 n n:1 n:1 n:1 , 220 D 20 10 10 , 0 H

Model CRI-100H Constant Rate Injector (EOX Mode)
The Constant Rate Injector (EOX mode) allows EOX (extractable organic halogen compounds) to be measured.
SPECIFICATIONS
Syringe Injection Rate Injection Volume Power Supply Dimensions Weight 250 0.4 2.0 Max. 2.0 AC100/115/230/240V, 50/60Hz, 40VA Approx. 320 Approx. 6
/sec.

Model POX-100 POX Sparger
The POX Sparger allows measurement of POX (purgeable organic halogen compounds).

Gastight Microsyringe

SPECIFICATIONS
Sample Volume Heater Temperature Power Supply Dimensions Weight Approx. 6 100 Room temperature 60 AC100/115/230/240V, 50/60Hz, 150VA

0

3

Sample injection rate is normally 1.0

Using AOX Auto Sampler Model Auto AOX-100 enables quick measurement of AOX in waste water, tap water, and underground water. Epoch-making AOX sampler was made possible by technology fostered in Germany which is advanced in AOX.

Features

The needs for measuring AOX in waste water, factory waste water, tap water and underground of our own low-blank activated carbon and automation technologies.
A maximum of 40 columns can be set on the sample table (carousel). Samples are measured automatically by lining up columns which have adsorbed AOX. The carousel is purged by Argon gas, effectively preventing contamination from the atmosphere. The activated carbon columns lined up on the carousel are extruded into a sample boat, and placed inside an electric furnace by the built-in Auto Boat Controller (ABC). Ash remaining in the boat is discarded when measurement is complete.

water are growing on a global scale. Mitsubishi has achieved maximum performance by means

AOX Automation System
Total Organic Halogen Analyzer Model TOX-100 (With AOX Auto Sampler) TOX-100 Main Unit PC Chlorine Titration Cell Unit (Option) AOX Auto Sampler Model AutoAOX-100 (Option)

Measurement Principle

1

Adsorption and W ashing

2

Column Preparation

Preparation of AC Columns.

Adsorption and washing.

Set AOX Columns to the Carousel. (Max 40 Columns)

3

Carbon Introduction

Carbon is pushed into sample boat.

4

Combustion and T itration

5

Ash Waste

The built-in ABC moves to the furnace zone.

After the titration is completed, than the ash is discarded.

Specifications
AOX Auto Sampler Model AutoAOX-100
Column Pusher Sample Inlet Shutter Carousel (40 Columns) Column Sensor Tower Safety Cover (Inside :Ar gas purge)

Standard Specifications
Model Carousel (Sample Tray) Sample Introduction Disposal of Waste Carousel Atmosphere Gas Requirements Power Supply Dimensions and Weight AOX Auto Sampler Model AutoAOX-100 40 Columns By Built-in Automatic Boat Controller Waste container for ash and ceramic material Argon gas purged Argon : Purity 99.98% or more, 290-490kPa Oxygen : Purity 99.7% or more, 290-490kPa AC 100/115/230/240V, 50/60Hz, 100VA Approx. 550 (W) x 350 (D) x 140 (H) mm, Approx. 15kg

Waste Container

Standard Specifications
Model
Method Oxidation Decomposition Furnace Temperature Samples Detection Method Detection Electrodes Titration Control Measuring Range Sample Size Detection Limit *4

Total Sulfur/Chlorine Analyzer
Oxidative pyloysis-coulometric titration Quartz tube combustion method Max. 1,100°C

Total Organic Halogen Analyzer

Liquids, solids and gaseous samples *1 Oxidation-reduction potential (detection of potential dif ference by an electrode) Cl: Silver electrode, S: Platinum electrode Silver electrode Automatic electrolytic current control 0.1-50?g (Cl), 0.05-50?g (S) (normal sample: combustible at 1,100°C or less without obstruction) Liquid *2: 50?/ or less, Solid 30mg or less 0.1 ppm (Cl) : when optional Constant Rate Injector (CRI-100H) is used. (0.1 ppm Chlorine standard sample 200 ?l is injected.) 0.2 ppm (S) : when optional Constant Rate Injector (CRI-100H)is used. (0.2 ppm Sulfur standard sample 200 ?l is injected.)
Concentration 500~/ml 50~/ml 5~/ml 100~/ml 10~/ml
Standard Samples

0.1-50?g (Cl), 0.05-50?g (S) (normal sample: combustible at 1,100°C or less without obstruction) Liquid *3: 10-200 ml

Reproducibility (by standard sample)

Sample Size 10 ?l 20 ?l 100 ?l *5 20 ml 100 ml

CI Recovery(%) 95~105 80~105 65~110 RSD(%)

S

AOX RSD(%)

<3 <5 <10

Recovery(%) 75~90 60~80 40~60

<3 <5 <10

Recovery(%)

RSD(%)

95~105 80~120

<3 <10

Cl: 2,4-dinitrochlorobenzene solution AOX: 2,4,6-trichlorophenol solution

S: Dimethylsulfoxide solution

Measurement Time Data Processing Function Display Function Printing Function Keyboard Interface Gas Requirements Power Supply Dimensions and Weight

Within 10 min/measurement when measuring 2?g *6 Using a personal computer Displayed on a PC-CRT Printout using an external printer *7 PC full keyboard PC Input/Output (RS232C): 1 channel Balance Input (RS232C): 1 channel Argon (purity: 99.98% or more, 290-490 kPa) Oxygen (purity: 99.7% or more, 290-490 kPa) *8 Main Unit: AC 100/115/230/240 V, 50/60 Hz 1,000 VA ABC: AC 100/115/230/240 V, 50/60 Hz, 40 VA Main unit: Approx. 550(W) x 360(D) x 430(H)mm , Approx. 36 ABC: Approx. 440(W) x 250(D) x 180(H) mm , Approx. 10

Processor RAM HD Drive Display Printer

Personal Computer (System Requirements to Run TOX-100 System Program) *9 Pentium?75 MHz or higher 16 MB or higher Requires at least 50 MB of available disk space 3.5-inch floppy disk drive and CD-ROM drive Display resolution of at least 640 x 480 Windows?95-compatible printer

*1. The optional Gas Injector is needed for measuring gaseous samples. *2. When used with the opional Constant Rate Injector, more quantity of liquid sample (max. 250 ) could be injected. *3. When used with the optional Adsorption Module. *4. The minimum limit of determination is different from the detection limit. *5. When used with the optional Constant Rate Injector. *6. Measurement time depends on the absolute quantity of the sample. *7. A printer is needed for printing reports. *8. 1kg/cm2 = 98.066kPa *9. Available only with the English-language version of Windows?95/98. The specifications for the personal computer are minimum requirements to run the TOX-100 System Program. Company and product names contained herein are the trademarks or registered trademarks of the companies concerned.
Note; Follow the instructions on the Manual to correctly install, connect and operate the instruments. Content of the Catalogue is subject to change without prior notice when improvements are made in the performance. The actual colors of the machine may appear different from colors printed in the Catalogue.

Exclusive US Distributor:

COSA INSTRUMENT CORPORATION 55 Oak Street, Norwood, NJ 07648 Tel: (201) 767-6600 Fax: (201) 767-6804 7125 North Loop East, Houston, TX 77028 Tel.: (713) 947-9591Fax.: (713) 947-7549 e-mail: cosa@cosaic.com www.cosa-instrument.com