Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, Illinois 61032

Basic Switches Hermetically Sealed
GENERAL INFORMATION HM switches are not generally recommended for 115 VAC, 60 Hz. If you have a 60 Hz application in the milliamp range, or applications that require the switch to function electrically during exposure to sub-freezing temperatures, contact the 800 number for special design variations that are available.

HM Series
FEATURES ? Hermetically sealed per enclosure design symbol 5, MIL-S-8805 ? Power load switching capability up to 4 amperes, 28 VDC and 115 VAC, 400 Hz ? Temperature tolerance from –85°F to +250°F (–65°C to +121°C) ? High temperature construction for use from –85°F to +500°F (–65°C to +260°C) ? Variety of auxiliary actuators ? Choice of terminal styles ? Gold contacts for special applications ? Military standard construction with listings on the MIL-S-8805 qualified products list.

ELECTRICAL RATINGS
Circuitry Single-Pole Double-Throw Single-Pole Double-Throw Single-Pole Double-Throw Single-Pole Double-Throw Single-Pole Double-Throw H I Electrical Rating Code 1 amp res., 0.25 amp ind., 28 vdc. 4 amps res., 2 amps ind., 0.5 amps lamp load, 115 vac, 400 Hz. 4 amps res., 2 amps ind., 1 amp lamp load, 28 vdc
1

J K L

?2 amp res., 1?4 amp ind. (sea level or 70,000 ft.), 28 vdc 3 amps res., 1 amp ind. (sea level or 70,000 ft.), 28 vdc 1 amp res. or ind. (sea level), 115 vac., 400 Hz. 3 amp res., 1 amp ind., 28 vdc 1 amp res., 1 amp ind., 115 vac, 400 Hz.

APPLICATION NOTES 1. Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. Catalog listings in the 5, 6, 15, and 16HM Series use silver cadmium oxide contacts. If you have specific questions, contact the MICRO SWITCH Application Center at 1-800-537-6945. 2. For applications involving non-arcing loads, catalog listings in the 9, 10, 19 and 20HM Series are recommended. 3. The 1, 2, 5, and 6HM Series are recommended for use only in 3 to 4 amp range applications.

80

Honeywell Sensing and Control

For application help: call 1-800-537-6945.

Basic Switches Hermetically Sealed

HM Series
Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position.

ORDER GUIDE
Operating Characteristics Electrical Rating Code K O.F. max. R.F. min. Newtons Newtons ounces ounces 1,95 7 0,28 1 P .T. max. mm inches 0,76 .030 O.P . O.T. min. D.T. max. mm mm mm inches inches inches ±.015 (0,38 mm) 0,08 .003 0,15 .006 8,38 .330

Catalog Listing 11HM1 (MS27216-5)

Recommended For Most applications. Exceeds MIL-S-8805 requirements for shock and vibration. Applications requiring gold contacts Operating in temperatures to 300°F (149°C) Bifurcated gold contacts MIL-S-8805 application requirements 1 ft. (305mm) leads 5 foot (1524mm) long leads

13HM1 Fig. 1 15HM1

H L

1,95 7 1,95 7 1,95 7 1,95 7

0,28 1 0,28 1 0,28 1 0,28 1

0,76 .030 0,76 .030 0,76 .030 0,76 .030

0,08 .003 0,08 .003 0,08 .003 0,08 .003

0,15 .006 0,15 .006 0,15 .006 0,15 .006

8,38 .330 8,38 .330 8,38 .330 8,38 .330

9HM1 (MS27216-6) 2HM19-1 (MS27216-2)

J I

2HM19-5 (MS27216-4) Fig. 2 16HM1-1

I

1,95 7

0,28 1

0,76 .030

0,08 .003

0,15 .006

8,38 .330

High temperature to 500°F (260°C) flat spring

L

1,95 7

0,28 1

0,76 .030

0,08 .003

0,15 .006

8,38 .330

Fig. 3 15HM2 Operating in temperatures to +500°F (260°C) with weld tab termination. No potting. L 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330

Sealed/High Temperature

Fig. 4

HM MOUNTING A force spreading plate is recommended to reduce the chance of product damage due to excessive mounting force. MOUNTING PLATE
19PA137-HM

NOTE Torque on #2 mounting screws must be restricted to 1.5 inch pounds max. to prevent switch damage. The force spreading mounting plate used as shown will allow up to 2.5 inch pounds of mounting torque.

For application help: call 1-800-537-6945.

Honeywell Sensing and Control

81

Basic Switches Hermetically Sealed

HM Series
Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position; F.P . — Free Position.

AUXILIARY ACTUATORS FOR HM SWITCHES ORDER GUIDE (Switches are not included)
Operating Characteristics with Actuator Mounted on a 6HM1-1 Catalog Listing JS-254 Temp. (Max.) 500°F (260°C) O.F. max. R.F. min. Newtons Newtons ounces ounces 2,50 9 0,56 2 P .T. max. mm inches — O.T. min. D.T. max. mm mm inches inches 0,76 .030 0,76 .030 O.P . mm inches F.P . mm inches

Description Leaf

8,64 12,2 .340 approx. .480 approx.

Fig. 5 JS-151 Roller leaf 500°F (260°C) 2,50 9 0,56 2 — 0,76 .030 0,76 .030 14 17,5 .550 approx. .690 approx.

Fig. 6 JS-307 Straight lever 500°F (260°C) 0,42 1.5 0,03 .11 3,18 .125 approx. 0,64 .025 1,42 .056 10,3 .406 approx.

Fig. 7 JS-308 Roller lever 500°F (260°C) 0,42 1.5 0,03 .11 3,18 .125 approx. 0,64 .025 1,42 .056 14,3 .562 approx.

Fig. 8

MOUNTING TORQUE: JS-254 2.5 inch pounds all others 1.5 inch pounds See optional mounting plate – previous page.

All standard JS actuators in the SM Section of Catalog 10 can be used with the HM line. However, hardware, insulator, and oil impregnated roller supplied with these actuators may not provide the required service at temperatures above 250°F (121°C).

82

Honeywell Sensing and Control

For application help: call 1-800-537-6945.

Basic Switches Hermetically Sealed
MOUNTING DIMENSIONS (For reference only)

HM Series

Fig. 1

Fig. 2

Fig. 3

Fig. 4

AUXILIARY ACTUATORS

Sealed/High Temperature

Fig. 5

Fig. 6

Fig. 7

Fig. 8

For application help: call 1-800-537-6945.

Honeywell Sensing and Control

83



相关文章:
...皮质激素C.雌激素D.孕激素E.尿促性腺激素(HM_答案_百度高考...
促排卵药物有:() A.雄激素B.肾上腺皮质激素C.雌激素D.孕激素E.尿促性腺激素(HMG)_答案解析_2016年_一模/二模/三模/联考_图文_百度高考
设m(0°,30°E)、n(23.5°S,30°E)两地正午太阳高度分...
设m(0°,30°E)、n(23.5°S,30°E)两地正午太阳高度分别为Hm和Hn,判断下列选项正确的是 AHm和Hn不可能在同一天达到最小值 B每年有两个时刻Hm=Hn C每年...
海尔FCD-JTHML 说明书
热水出口 B 冷水进口 C 加热管 D 搪瓷内胆 E 进水管 F 出水管 J 控制板 K 镁棒 随机附件:线控盒 喷头、 软 电热水 安全阀 产品型号 器 (台) () (...
土地管理基础:土地概念(33)
A:投资利润率 B:财务净现值 C:内部收益率 D:销售利润率 E:现金回报率 21、居住面积密度等于()(m2hm-2)。 A. B. C. D. 22、建筑地段地租具有的特征...
...过F作FH⊥BE,交AB于G,过H作HM⊥AB于M_答案_百度高考
如图,正方形ABCD中,E、F分别为边AD、DC上的点,且AE=FC,过F作FH⊥BE,交AB于G,过H作HM⊥AB于M,若AB=6,AE=2,则下列结论中:①∠BGF=∠CFB;②DH=EH+...
高考 高中 物理 知识点 大全 分章节
上升最大高度 Hm =Vo2/2g(抛出点算起) 5.往返时间 t=2Vo/g (从抛出落...机械能守恒定律: Δ E=0 或 EK1+EP1=EK2+EP2 也可以 是 mv12/2+mgh1=...
2015年土地估价相关知识:保险的概念
A:城市规划 B:土地利用年度计划 C:村庄规划 D:集镇规划 E:35%~50% 15、...A.1620 B.1636 C.1800 D.1980 24、居住面积密度等于()(m2hm-2)。 A. ...
2017土地估价师案例:农用地基准地价评估2模拟试题
A:资产负债表 B:利润表 C:现金流量表 D:利润分配表 E:土地 8、地籍是土地...停机坪 B.幼儿园 C.军事设施 D.商业娱乐设施 5、居住面积密度等于()(m2hm-...
LOSMA过滤器、LOSMA空气过滤器、LOSMA、LOSMA冷却液过...
(6600-30-2-0.37) 传感器 KSS 400 P3K-TSSL 传感器 HMFB-VT V=200mm ...0-25bar 温度开关 KFL-E/B/O/O/S/N-930-870-790-180 编码器 HS35-...
2017年土地估价师:地籍的含义
A.统计整理 B.汇兑调查 C.统计调查 D.统计分析 E.统计设计 2、支路以下道路...使用权的转让有三种方式,即出售、交换、赠与 16、居住面积密度等于()(m2hm-2...
更多相关标签: