当前位置:首页 >> 信息与通信 >>

8960配置手册


Agilent 8960 Series 10 Wireless Communications Test Set
Configuration Guide

This configuration guide describes how to configure a new 8960 test set for single or multiple wire

less formats and lists the upgrades available for existing 8960 test sets.

Notice
For the newest 8960 configuration information, select the 8960 Configuration guide from the Key Library at www.agilent.com/find/8960

8960 Series 10 Wireless Test Set – Mainframe, Applications, and Software
The building blocks of the 8960 are an E5515 test set mainframe and mobile test applications (TAs) or lab applications (LAs). Test applications provide parametric test capability. Lab applications test parametric performance and add signaling functionality. E5515 options enable specific TAs and LAs, offer support choices, offer documentation choices, and give rack or handle alternatives. TA and LA options offer documentation choices. Wireless Test Manager is a family of easy-to-use 8960 test automation software. Wireless Test Manager runs on a Windows? PC.

Configuring a New 8960 for Your Application
Table 1 shows the recommended or required options to purchase with a new 8960 in order to test a specific wireless format. If adding a test or lab application to an existing mainframe, refer to the section entitled, Adding wireless formats to your 8960 test set.

Table 1. New purchase configuration information Wireless technology format
Formats for test applications AMPS/136 (TDMA) cdma2000/IS-95/AMPS cdma2000 Rel A New Control Channels W-CDMA W-CDMA Video Test 1xEV-DO GSM GPRS EGPRS GSM and GPRS GSM, GPRS, and EGPRS Test Application Fast Switching3 Test Application Fast Switching3,4 Test Application Suite5 UMTS Test Application Suite6 Formats for lab applications GSM/GPRS cdma20007 W-CDMA7 EGPRS8 1xEV-DO Lab Application Fast Switching10 UMTS Lab Application Suite11 Lab Application Suite12

TA, LA model (option)
Required E1961A E1962B E1962B-401 E1963A E1963A-401 E1966A E1968A-101 E1968A-102 E1968A-103 E1968A-201 E1968A-202 E1985D E1987A E1991B E1993A E6701D E6702B E6703C E6704A E6706A9 E6785C E6717A E6719A

Mainframe model
Required E5515C1 or B1 E5515C1 E5515C1 E5515C1 E5515C1 E5515C1 E5515C1 or B1 E5515C1 or B1 E5515C1 or B1 E5515C1 or B1 E5515C1 or B1 E5515C1 E5515C1 E5515C1 E5515C1 E5515C1 or B1 E5515C1 E5515C1 E5515C1 or B1 E5515C1 E5515C1 E5515C1 E5515C1

Mainframe options (model no. - option)
Required 003 003 003 003 003 002 002 002 002 002 002, 003 002, 003 002, 003 002,003 002 003 003 002 003 002, 003 002,003 002, 003 Recommended 002, 0032 002 002 002 002 002 0032 0032 003 0032 0032

Wireless Test Manager
E6563A, E6571A E6560A/C, E6571A/C E6560A/C, E6571A/C E6562A/C, E6571A/C E6562A/C, E6571A/C E6564A, E6571A E6566A/C, E6571A/C E6566A/C, E6571A/C E6566C, E6571C E6566A/C, E6571A/C E6566C, E6571C E6569A/C, E6571A/C E6569A/C, E6571A/C E6569A/C, E6571A/C E6569A/C, E6571A/C E6566A/C E6560A/C E6562A/C E6566C Not supported E6569A/C E6569A/C, E6571A/C E6569A/C

0032 002 002 003 002

2

1. New E5515s will not work with older revision or discontinued applications. For information on application compatibility, go to www.agilent.com/find/E5515 and select either E5515B or E5515C Release Notes from the Key Library. 2. Option 003 is not available to order on new E5515Bs. 3. Includes E1985B for GSM/GPRS to AMPS/136 to W-CDMA, E1985C for GSM/GPRS to cdma2000/IS-95/AMPS, and E1985E for cdma2000/ IS-95/AMPS to 1xEV-DO. GSM/GPRS fast switching includes EGPRS. Two or more TAs are required for fast switching. For example, E1962B and E1968A-101 are needed to switch between cdma2000 and GSM. GSM/GPRS fast switching includes EGPRS. 4. E1987A allows fast switching across all TA technology formats. E1985 applications switch across specified formats. 5. E1991B TA Suite includes TAs for cdma2000, 1xEV-DO, IS-95, W-CDMA, GSM, GPRS, EGPRS, 136 (TDMA), AMPS, and fast switching TAs. Model numbers included are E1961A, E1962B, E1963A, E1966A, E1968A-202, E1985D, and E1987A. Does not include E1962B-401 or E1963A-401. 6. E1993A UMTS TA Suite includes TAs for W-CDMA, GSM, GPRS, EGPRS, and fast switching TAs. Model numbers included are E1963A, E1968A-202, E1985B, and E1987A. Does not include E1963A-401. 7. Fading is available. Contact your Agilent Sales Representative or go to the Web for information. Go to www.agilent.com/find/E6702B for cdma2000 fading. Go to www.agilent.com/find/E6703C for W-CDMA fading. 8. E6701D LA required for E6704A LA. 9. E6706A 1xEV-DO lab application is available only as a TA to LA upgrade. Start with 8960 with E1966A TA installed. Upgrade to E6706A LA using E6706AU-001. 10. E6785C fast switches from GSM/GPRS to W-CDMA. Requires E6701D and E6703C LAs. Order E6704A LA to add EGPRS to fast switching. 11. E6717A UMTS LA Suite includes LAs for W-CDMA, GSM, GPRS, and EGPRS. Model numbers included are E6701D, E6703C, E6704A, and E6785C. 12. E6719B LA Suite includes LAs for cdma2000, W-CDMA, GSM, GPRS, and EGPRS. Model numbers included are E6701D, E6702B, E6703C, E6704A, and E6785C.

Test Set Mainframes
E5515C E5515B 8960 Series 10 mainframes. (Require at least one Agilent Technologies test or lab application. E5515C is required for CDMA capability in a new test set. Older revision and discontinued applications are not compatible with new E5515s. Trying to run incompatible applications will cause new E5515s to lock-up. Specifically, E5515B S/N < GB45080001 and E5515C < GB45070001 do not work with applications released before January 2005 or the following discontinued applications: E1960A, E1964A, E1985A, E1992A, E6701A/B, E6702A, E6703A, and E6785A/B.) For more information on application compatibility, go to www.agilent.com/find/8960 and select E5515C or E5515B Release Notes from the Key Library.

Test set mainframe options
E5515B-002 E5515C-002 E5515C-003 Second RF source. (Required for all GSM, GPRS, and EGPRS applications.) Flexible CDMA base station emulator. (Required for all cdma2000/ IS-95/AMPS, W-CDMA, and 1xEV-DO applications. Not available in new E5515Bs.) E6571A Wireless Test Manager run-time license. Compatible with E656xA/B/C Wireless Test Manager models. Requires a PC with parallel port.

E5515C-370

E5515B-ABA Documentation for applications purchased with a mainframe. E5515C-ABA Includes all 8960 test and lab application documentation. Consists of a CD-ROM with programming guides, getting started guides, and paper copies of GPIB syntax guides. US-English localization. To download documentation in other languages, go to www.agilent.com/find/8960, select product model, Key Libraries, and download the Help files. Not all languages are available. E5515B-0B0 E5515C-0B0 E5515B-AX4 E5515C-AX4 E5515B-AX5 E5515C-AX5 E5515B-UK6 E5515C-UK6 Delete documentation on applications purchased with a mainframe. Rack flange kit without handles. Rack flange kit with handles. Commercial calibration certificate with test data.

Warranty and service
3-year customer return repair service 5-year customer return repair service

Calibration
3-year customer return calibration service 5-year customer return calibration service

Operational verification
E5515B-B8A E5515C-B8A Operation verification at installation. Contact your Agilent Sales Representative for more information.

Accessories
Programmed test SIM cards E5515-10007 UMTS (W-CDMA) USIM card (included with new E6703C LA) 08922-61887 GSM SIM card (programmed micro-size, 15 mm x 25 mm) 08922-80047 GSM SIM card (programmed, credit card size)

3

Test Applications
E1961A E1962B AMPS/136 mobile test application. (Requires E5515C or E5515B.) cdma2000/IS-95/AMPS mobile test application. (Requires E5515C and E5515C-003.) E1962B-401 cdma2000 Rel A New Control Channels. (Requires E5515C and E5515C-003.) E1963A E1966A E1968A W-CDMA mobile test application. (Requires E5515C and E5515C-003.) E1963A-401 W-CDMA video phone test. (Requires E5515C and E5515C-003.) 1xEV-DO terminal test application. (Requires E5515C and E5515C-003.) E1968A GSM/GPRS mobile test application. GSM, GPRS and EGPRS wireless technology functionality is available. Must specify an option for a specific format or combination of formats. E1968A-101 E1968A-102 E1968A-103 E1968A-201 E1968A-202 E1985D GSM functionality. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.) GPRS functionality. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.) EGPRS functionality. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.) GSM/GPRS functionality. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.) GSM/GPRS/EGPRS functionality. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.)

Fast switching test applications. Includes E1985B for GSM, GPRS, and EGPRS to AMPS, and 136 or W-CDMA fast switch; E1985C for GSM, GPRS, and EGPRS to cdma2000, IS-95, and AMPS fast switch; and E1985E for cdma2000, IS-95, and AMPS to 1xEV-DO fast switch. (Requires E5515C, TAs, and E5515 options for the wireless formats to be switched.) New fast switching test application. E1987A switches across all TA formats. E1985 applications only switch across some formats. (Requires E5515C, at least two TAs, and E5515 options for the wireless formats to be switched.) 8960 test application suite. Includes test applications for GSM, GPRS, EGPRS, AMPS, 136, cdma2000, IS-95, 1xEV-DO, and W-CDMA. Contains E1968A-202, E1961A, E1962B, E1963A, and E1966A TAs, plus E1985D and E1987A fast switching TAs. Order E1962B-401 cdma2000 Rel A and E1963A-401 W-CDMA video phone test TA options separately; they are not included in the TA suite. (Requires E5515C, E5515C-002, and E5515C-003. E1991B is for installation on a single 8960 test set.) 8960 UMTS test application suite. Includes TAs for GSM, GPRS, EGPRS, and W-CDMA. Contains E1968A-202 and E1963A TAs, plus E1987A and E1985B fast switching TAs. Order E1963A-401 W-CDMA video phone test TA option separately; it is not included in the UMTS TA suite. (Requires E5515C, E5515C-002, and E5515C-003. E1993A is for installation on a single 8960 test set.) If adding a test application to an existing mainframe, see the section entitled, Adding wireless formats to your 8960 test set.

E1987A

E1991B

E1993A

Note:

4

Test application includes
? Test application license. ? 8960 documentation set. (Includes documentation for all 8960 TAs and LAs. Must specify language localization option. When ordered with an E5515 mainframe use E5515 application documentation options.) ? If ordering more than one TA, specify language localization option for one TA and order Option 0B0 on the other TAs to avoid receiving multiple 8960 documentation sets.

Test application options available when ordered standalone (without an E5515 mainframe)
TA Model#-010 Test application installation set for test applications purchased standalone. (CD-ROM with the necessary files and utilities needed for loading test applications. Test applications can be downloaded from www.agilent.com/find/8960ta. Option 010 is recommended if you do not have high-speed Internet access.)

TA Model#-ABA Documentation for test applications purchased standalone. Includes all test and lab application documentation. Consists of CD-ROM with programming guides, getting started guides, and paper copies of GPIB syntax guides. US-English localization. To download document in other languages, go to www.agilent.com/find/8960, select Key Libraries and download the Help files. Not all languages are available. TA Model#-0B0 Delete documentation.

5

Lab Applications
E6701D E6702B E6703C E6704A E6706A GSM/GPRS lab application. (Requires E5515C and E5515C-002, or E5515B and E5515B-002.) cdma2000 lab application. (Requires E5515C and E5515C-003.) W-CDMA lab application. (Requires E5515C and E5515C-003.) Includes E5515-10007 UMTS (W-CDMA) USIM card. EGPRS lab application. (Requires E6701D and E5515C with E5515C-002 or E5515B with E5515B-002.) 1xEV-DO lab application. (Requires E5515C, E5515C-003, E1966A, and E6706AU-001. Currently only available as an upgrade from E1966A TA to E6706A.) Fast switching lab application for GSM/GPRS/EGPRS_W-CDMA. (Requires E6701D, E6703C, E5515C, E5515C-002, and E5515C-003. For EGPRS capability, add E6704A.) 8960 lab application UMTS suite. Includes LAs for GSM, GPRS, EGPRS, and W-CDMA. Contains E6701D, E6703C, E6704A LAs and E6785C fast switching LA. (Requires E5515C, E5515C-002, and E5515C-003. E6717A is for installation on a single 8960 test set.) Lab application suite. Includes LAs for GSM, GPRS, EGPRS, cdma2000, W-CDMA, and fast switching. Contains E6701D, E6702B, E6703C, E6704A LAs and E6785C fast switching LA. (Requires E5515C, E5515C-002, and E5515C-003. E6719B is for installation on a single 8960 test set.) If adding a lab application to an existing mainframe, see the section entitled, Adding wireless formats to your 8960 test set.

E6785C

E6717A

E6719B

Note:

Lab applications include
? Lab application license. ? Wireless protocol advisor (WPA) software for specified format. WPA is PC software that works with 8960 lab applications to capture and analyze wireless protocols. ? 8960 application documentation. (Must specify localization option. When ordered with E5515 mainframe use E5515 application documentation options.) ? If ordering more than one LA, specify language localization option for one LA and order Option 0B0 on the other LAs to avoid receiving multiple 8960 documentation sets.

6

Lab application options available when ordered standalone (without an E5515 mainframe)
LA Model#-010 Lab application installation set. (CD-ROM with the necessary files and utilities needed for loading test applications. Lab applications can be downloaded from www.agilent.com/find/8960la. Option 010 is recommended if you do not have high-speed Internet access.) LA Model#-ABA Documentation for lab applications purchased standalone. Includes all test and lab application documentation. Consists of CD-ROM with programming guides, getting started guides, and paper copies of GPIB syntax guides. US-English localization. To download document in other languages, go to www.agilent.com/find/8960, select Key Libraries, and download the Help files. Not all languages are available. LA Model#-0B0 Delete documentation.

Wireless protocol applications (WPA) ordered standalone (without an LA)
E6584A PC software that works with 8960 lab applications to capture and analyze wireless protocols. (Included with LA. To order without LA, order E6584A and option to specify format.) GSM/GPRS/EGPRS decodes for WPA software. cdma2000 decodes for WPA software W-CDMA decodes for WPA software

E6584A-001 E6584A-002 E6584A-003

7

Wireless Test Manager software
Wireless Test Managers require a specific model and revision of TA and LA. See the individual test manager data sheet or overview to determine compatible TAs and LAs at www.agilent.com/find/wtmanagers.

Find your software development platform and select your products...
Platform
Visual Studio .NET? E6560C E6562C E6566C E6569C E6571C Visual Basic 6? E6560A E6562A E6563A E6564A E6566A E6568B E6569B E6571A N4019A N4018A cdma2000/IS-95 Wireless Test Manager W-CDMA Wireless Test Manager AMPS/136 Wireless Test Manager 1xEV-DO Wireless Test Manager GSM/GPRS Wireless Test Manager W-CDMA/GSM/GPRS Wireless Test Manager Wireless Test Manager Suite Wireless Test Manager Run-Time License for operation on E656xA/B and E656xC versions. Bluetooth? Wireless Test Manager Bluetooth? wireless test manager run-time license cdma2000/IS-95/AMPS Wireless Test Manager W-CDMA Wireless Test Manager GSM/GPRS/EGPRS Wireless Test Manager Wireless Test Manager Suite Wireless Test Manager Run-Time License for operation only on E656xC versions

Product

Description

8

Upgrading an existing 8960 test set
The 8960 is a flexible test set that can be upgraded to meet your changing wireless test needs. There are four types of 8960 upgrades 1. 2. 3. 4. updating an existing test/lab application upgrading an application to a new model number upgrading a test application to a lab application adding a wireless technology format

To get timely information about 8960 application improvements, register for Agilent Email Updates at www.agilent.com/find/emailupdates.

1. Updating an existing application to get the newest features
TAs and LAs are periodically revised to add new functionality, improve performance, or resolve known issues. TA revision updates are free. LA revision updates within a model number are free (E6703B B.01.xx to E6703B B.02.xx.) To upgrade an LA to a new model number (E6703B to E6703C), refer to 2. Upgrading an existing application to a new model. A valid application license is required. Free TA and LA downloads are available at www.agilent.com/find/8960ta. Some new features are part of free upgrades, other new features require a TA option upgrade, LA model upgrade, or an E5515 mainframe hardware upgrade. To determine if a hardware upgrade is required to enable a feature listed in Table 2, please contact your Agilent Sales Representative.

Table 2. New feature upgrades
Application Test applications E1962B E1963A E1963A E1968A-103 Lab applications E6701D/ E6704A E6701D/ E6704A E6702B E6702B E6703C E6703C E6703C E6703C GSM/GPRS/EGPRS GSM/GPRS/ EGPRS cdma2000 cdma2000 W-CDMA W-CDMA W-CDMA W-CDMA EGPRS Class 10 measurements (full multi-slot) EGPRS Class 12 signaling cdma2000 Rel A new control channels Fading 384K data throughput BLER for asynchronous channels Fading Video test Format cdma2000 W-CDMA W-CDMA EGPRS Feature cdma2000 Rel A new control channels Video test BLER for asynchronous channels Class 10 measurements (full multi-slot)

9

2. Upgrading an existing application to a new model number
Upgrading existing TAs and LAs to new model numbers (e.g. E6701C to E6701D) can provide significant new functionality and feature improvements. LA upgrades to newer model numbers are offered as an upgrade product. TA upgrades may be upgrade products or free downloads. TA and LA upgrades are customer installable. See Table 3 below for available TA and LA upgrades. Some upgrades may require an E5515 hardware upgrade to run or enable specific features. Contact your Agilent Sales Representative for specific application upgrade information.

Table 3. Application model number upgrades
Current application E6701B E6701C E6702A E6703A E6703B E1960A E1964A E1985A E1985B E1985A/B/C/E Recommended upgrade E6701D E6701D E6702B E6703C E6703C E1968A-101? E1968A-102? E1985B, E1985C, and E1985E? Add E1985C and E1985E? E1987A? Upgrade description GSM/GPRS LA upgrade GSM/GPRS LA upgrade cdma2000 LA upgrade W-CDMA LA upgrade W-CDMA LA upgrade GSM TA functionality GPRS TA functionality Add new fast switching TAs Add new fast switching TAs Upgrade to new E1987A fast switching TA Order E6701DU-001 E6701DU-002 E6702BU-002 E6703CU-002 E6703CU-003 Free download Free download Free download Free download Free download

? May require a hardware upgrade. Contact your Agilent Sales Representative for more information.

10

3. Upgrading a test application to a lab application
Upgrading a TA to an LA (e.g. E1962B to E6702B) is customer installed; TA to LA upgrades cannot be ordered pre-installed on new instruments. Some TA to LA upgrades may require an E5515 mainframe hardware upgrade. Contact your Agilent Sales Representative for compatibility information.

Table 4. TA to LA upgrade products
TA to upgrade from E1962B E1963A E1966A LA to upgrade to E6702B E6703C E6706A Upgrade description Upgrade from cdma2000 TA to cdma2000 LA Upgrade from W-CDMA TA to W-CDMA LA Upgrade from 1xEV-DO TA to 1xEV-DO LA Order E6702BU-001 E6703CU-001 E6706AU-001

4. Adding wireless technology formats to your 8960 test set
You can add any TA or LA to an existing E5515B or E5515C. Being able to purchase another wireless format for your existing test set may save considerable expense when compared to purchasing a new E5515C. Adding a new TA or LA to an existing E5515B or E5515C may require a hardware upgrade. Contact your Agilent Sales Representative for specific upgrade order and delivery information. Important: Existing TAs and LAs installed on an E5515B or E5515C may have to be updated to a newer version after hardware upgrade.

11

For more product information visit our Web site at: www.agilent.com/find/8960

Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.” Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent’s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit

www.agilent.com/find/connectivity
for more information. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:

www.agilent.com/find/contactus
Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080)769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com
Contacts revised: 1/12/05

Agilent Email Updates
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.

Windows, Visual Basic, and Visual Studio .NET are U.S. registered trademarks of Microsoft Corp. Bluetooth is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, Inc.

Product specifications and descriptions in this document subject to change without notice.

? Agilent Technologies, Inc. 2002, 2003, 2004, 2005 Printed in USA, March 1, 2005 5968-7873E


相关文章:
8960用例参数配置
8960用例参数配置_计算机软件及应用_IT/计算机_专业资料。8960 开机后总体配置: 1:SYSTEM CONFIG Control?Format Switch 选择 WCDMA 2:Call Control?Cell Parameters...
安捷伦8960实用简易操作说明
安捷伦8960实用简易操作说明_计算机硬件及网络_IT/计算机_专业资料。适用于手机工厂员工操作指导安捷仑 8960 综合测试仪是 GSM 和 CDMA 手机测试常见的测试仪器,现把...
8960个人使用指南
8960个人使用指南_信息与通信_工程科技_专业资料。实用的使用手册,一些基本的参数...8960配置手册 12页 免费 8960操作 110页 4下载券 8960校准过程 1页 免费 8960...
安捷伦8960综测仪操作指导
安捷伦8960综测仪操作指导_计算机软件及应用_IT/计算机_专业资料。介绍安捷伦8960综测仪的操作方法,使用指导 文档贡献者 赵兴国0614 贡献于2013-11-14 ...
EVDO 8960测试操作手册
EVDO 8960测试操作手册_信息与通信_工程科技_专业资料 暂无评价|0人阅读|0次下载|举报文档EVDO 8960测试操作手册_信息与通信_工程科技_专业资料。 ...
8960设置
8960设置_信息与通信_工程科技_专业资料。给通信行业同仁们提供下综测仪使用,今日...8960配置手册 12页 免费 8960校准过程 1页 免费 8960个人使用指南 5页 免费 ...
8960的3G使用说明
8960使用规范 11页 免费如要投诉违规内容,请到百度文库投诉中心;如要提出功能问题或意见建议,请点击此处进行反馈。 8960的3G使用说明 隐藏>> Agilent8960 关于 3G ...
WCDMA射频测试操作手册-8960图文版
WCDMA 射频测试操作手册——8960 图文版(V1.0) 修改记录文件编号 版本号 拟制人/ 修改人 拟制/修 改日期 更改理由 主要更改内容 (写要点即可) 无 注 1:...
8960!CMU200!全中文说明书 手机综测仪基本操作和设置
8960!CMU200!全中文说明书 手机综测仪基本操作和设置_信息与通信_工程科技_专业...System config 按下 System config 系统配置按钮进入仪器参数设置界面 点击 Instrume...
基于8960测试操作指导书
36 III 8960 测量原理及操作说明 第 1 章 基础知识 1.1 GSM 测量频率频道范围 PGSM EGSM DCS PCS TX Channel :1-124 RX Channel :1-124 TX Channel :1...
更多相关标签:
agilent 8960使用手册 | wm8960中文手册 | 天融信防火墙配置手册 | 华为交换机配置手册 | 华为s2700配置手册 | 华为s5700配置手册 | h3c s5500配置手册 | cisco路由器配置手册 |