当前位置:首页 >> 机械/仪表 >>

电加热器参数


?

General

This proposal covers the necessary requirements for technical terms concerning the design, material, procurement, fabrication, testing, and final report prepar

ation for item mentioned in below table:

Material Summary List No. 1 2 3 4 5 6 7 8 Item No. 2323-V-101/201 2323-V-102/202 2423-V-101 2423-V-201 2323-H-101/201 2323-H-102/202 2423-H-101 2423-H-201 Item Description HP缓冲罐 FLD DrumFLD罐 FLL Drum FLL Drum Electrical Heater电 加热器 Electrical Heater电 加热器 Electrical Heater电 加热器 Electrical Heater电 加热器 Base Material SS 316L SS 316L A 516-60N A 516-60N SS SS SS SS

Design设计 The materials, design, Pre-fabrication, fabrication and painting, marking, packing and shipping of the Vessel shallconform to ASME Sec.VIII Div.1. All mechanical calculation and fabrication drawings which prepared based on data sheet will be prepared and forwarded to client for approval.容器的材料,设计,制造前准备,制造, 喷漆,标记,包装,运输都应当符合ASME Sec.VIII Div.1.标准。所有基于订单的机械 计算,制造图纸都应当交友客户批准。

Design Specification for 2323-V-101/201

Item No. 1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Item Description 2323-V-101/201-HP Flare K.O. Drum Tag No.编号 Content名称 Wet/Dry Hydrocarbons 湿/干碳氢化合物 ASME Sec.VIII Div.1 Applicable Code适用标准 mm 2850/11000 Inside Diameter/Length内径/长度 Operating Pressure工作压力 barg 0 / 5.95 (Min/Max) o C AMB Operating Temperature工作压力 External Design Pressure外部设计 barg F.V. 压力 Internal Design Pressure内部设计压 barg 10 力 Design Temperature (Min/Max)设计 o C -0.496 温度(最高/低) mm 0 Corrosion Allowance腐蚀裕度 Corrosion Allowance for Internals内 mm 0 部组件内部件腐蚀裕度 Full/ E=1 Radiography /Joint Efficiency辐射/接口系数 No Post Weld Heat Treatment焊后热处理 Basic Wind Speed / T.O.G.Fact.基 36.12/ Exposure ‘D’曝 m/s 本风速/T.O.G.系数 光 UBC Zone 2B Earthquake地震强度 3 Kg/m No Lining/Density内衬/密度 Insulation Thickness / Type保温层 mm 30 / PP 厚度/种类 mm No Fire Proofing Thickness耐火厚度 Liquid Density(Min/Max)液体密度 Kg/m3 580/1000 (最小/大) m3 88.35 Capacity容积 Shop Test Pressure (Horizontal)车 barg 13 间测试压力(水平) Lethal Service Yes No Ladder &Platform扶梯/平台 No Code Stamping签章

3.8 Item 1 2
3

Construction Specification for 2323-V-101/201 Description Shell壳体 Head封头 Fabrication Weight制 造重量 Thickness 14 mm 14 mm
17380 Kg

4

Erection Weight建筑 重量

27020 Kg

Item
N1/N2 N3 N4 N5/N6 N7/N8 N9/N10 N11 N12 N13 N14/N15 N16/N17 N18 N19/N20 N21/N22 N23 M1

Qty.
2 1 1 2 2 2 1 1 1 2 2 1 2 2 1 1

Size/Sch/Thk mm
40”/-/13mm 40”/-/13mm 3”/80/3”/80/2”/160/2”/160/2”/160/2”/160/2”/160/3”/80/2”/160/2”/160/2”/160/ 2”/160/ 24”/-/10mm

Rating
150 150 150 300 300 300 300 300 300 150 150 150 300 300 150 150

Type
W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F

Service
Inlet入口 Gas Outlet出口气体出 口 Liquid Outlet出口 Level Bridle(Control) 液位计(控制) LI(Trips) LI(Trips) Pressure Instrument 压力表 TI(Trips) TI Drain排净口 Utility Connection公用 接头 Vent出口 LI(Trips) LI(Trips) Electrical Heater电加 热器电加热器 Manway走道
With Blind

Remark

With Vortex Breaker

Finalized by Heater Vendor由 供应商敲定

M2

1

24”/-/10mm

150

W.N.-R.F

Manway走道

Manway shall be supplied with cover, bolts, Gasket and internal hand grips acc. to STD.105走道应配齐STD 105 标准盖子,螺栓,垫片,内置手 柄

Design Specification for 2323-V-102/202 Item No. 1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Item Description 2323-V-102/202-LP Dry Flare Drum Tag No.编号 Content名称 Dry Hydrocarbons 干碳氢合物 ASME Sec.VIII Div.1 Applicable Code适用标准 mm 2000/6100 Inside Diameter/Length内径/长度 Operating Pressure工作压力 barg 0 / 1.5 (Min/Max) o C AMB Operating Temperature工作压力 External Design Pressure外部设计 barg F.V. 压力 Internal Design Pressure内部设计压 barg 3.5 力 Design Temperature (Min/Max)设计 o C -0.85 温度(最高/低) mm 0 Corrosion Allowance腐蚀裕度 Corrosion Allowance for Internals内 mm 0 部组件内部件腐蚀裕度 Full/ E=1 Radiography /Joint Efficiency辐射/接口系数 No Post Weld Heat Treatment焊后热处理 Basic Wind Speed / T.O.G.Fact.基 m/s 36.12/ Exposure曝光 ‘D’ 本风速/T.O.G.系数 UBC Zone 2B Earthquake地震强度 3 Kg/m No Lining/Density内衬/密度 Insulation Thickness / Type保温层 mm 30 / PP 厚度/种类 mm No Fire Proofing Thickness耐火厚度 Liquid Density(Min/Max)液体密度 Kg/m3 545/620 (最小/大) m3 21.24 Capacity容积 Shop Test Pressure (Horizontal)车 barg 4.55 间测试压力(水平) Lethal Service No Yes Ladder &Platform扶梯/平台

Construction Specification for 2323-V-102/202

Item 1 2
3 4

Description Shell壳体 Head封头 Fabrication Weight制造重 量 Erection Weight建筑重量

Thickness 11 mm 8 mm
6135 Kg 9935 Kg

Item
N1/N2 N3 N4 N5/N6 N7/N8 N9/N10 N11 N12 N13 N14/N15 N16 N17/N18 N19/N20 N21/N22

Qty.
2 1 1 2 2 2 1 1 1 2 1 2 2 2

Size/Sch/Thk mm
24”/20/24”/20/3”/80/3”/80/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/ 2”/160/

Rating
150 150 150 300 300 300 300 300 300 150 150 150 300 300

Type
W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F

Service
Inlet入口 Gas Outlet出口气体出口 Liquid Outlet出口 Level Bridle(Control)液 位计(控制) LI(Trips) LI(Trips) Pressure Instrument压 力表 TI(Trips) TI Utility Connection公用接 头 Vent出口 Drain排净口 LI(Trips) LI(Trips)

Remark

With Vortex Breaker带防涡器

With Blind带栅板

N23

1

-

150

W.N.-R.F

Electrical Heater电加热 器电加热器

M1

1

24”/20/-

150

W.N.-R.F

Manway走道

M2

1

24”/20/-

150

W.N.-R.F

Manway走道

Electrical Heater电加热器电加热器 duty:62 kw Finalized by Heater Vendor由供应商敲定 Manway shall be supplied with cover, bolts, Gasket and internal hand grips acc. to STD.105走道应 配齐STD 105标准盖子,螺栓,垫片, 内置手柄 Manway shall be supplied with cover, bolts, Gasket and internal hand grips acc. to STD.105走道应 配齐STD 105标准盖子,螺栓,垫片, 内置手柄

Design Specification for 2423-V-101 Item No. 1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Item Description 2423-V-101- Flare Drum Tag No.编号 Dry Hydrocarbons Content名称 ASME Sec.VIII Div.1 Applicable Code适用标准 mm 2000/6000 Inside Diameter/Length内径/长度 Operating Pressure工作压力 barg 0 / 0.25 (Min/Max) o C AMB Operating Temperature工作压力 External Design Pressure外部设计压 barg F.V. 力 Internal Design Pressure内部设计压 barg 3.5 力 Design Temperature (Min/Max)设计 o C -0.418181818 温度(最高/低) mm 1.5 Corrosion Allowance腐蚀裕度 Corrosion Allowance for Internals内 mm 0 部组件内部件腐蚀裕度 Full/ E=1 Radiography /Joint Efficiency辐射/接口系数 No Post Weld Heat Treatment焊后热处理 Basic Wind Speed / T.O.G.Fact.基本 m/s 36.12/ Exposure曝光 ‘D’ 风速/T.O.G.系数 UBC Zone 2B Earthquake地震强度 3 Kg/m No Lining/Density内衬/密度 Insulation Thickness / Type保温层厚 mm 30 / PP 度/种类 mm No Fire Proofing Thickness耐火厚度 Liquid Density(Min/Max)液体密度(最 Kg/m3 580/612 小/大) m3 21 Capacity容积 Shop Test Pressure (Horizontal)车间 barg 4.55 测试压力(水平)

22 23 24

Lethal Service Ladder &Platform扶梯/平台 Code Stamping签章

No Yes No

Construction Specification for 2423-V-101 Item 1 2
3 4

Description Shell壳体 Head封头 Fabrication Weight制造重 量 Erection Weight建筑重量

Thickness 14 mm 10 mm
6670 Kg 10080 Kg

Item
N1 N2 N3 N4/N5 N6/N7 N8/N9 N10/N11

Qty.
1 1 1 2 2 2 2

Size/Sch/Thk mm
30”/-/12mm 24”/-/10mm 3”/80/3”/80/2”/160/2”/160/2”/160/-

Rating
150 150 150 300 300 300 300

Type
W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F

Service
Inlet入口 Gas Outlet出口气体出 口 Liquid Outlet出口 LI(Trips) LI(Trips) LI(Trips) LI(Trips)

Remark

With Vortex Breaker带防涡器

N12 N13 N14/N21 N15 N16 N17 N18/N19 N20

1 1 2 1 1 1 2 1

2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/ 2”/160/ -

300 300 150 150 150 300 300 150

W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F

Pressure Instrument压 力表 TI Utility Connection公用 接头 Vent出口 Drain排净口 TI(Trips) Level Bridle(Control)液 位计(控制) Electrical Heater电加 热器电加热器
With Blind带栅板

M1

1

24”/-/10mm

150

W.N.-R.F

Manway走道

Finalized by Heater Vendor由供 应商敲定 Manway shall be supplied with cover, bolts, Gasket and internal hand grips acc. to STD.105走道 应配齐STD 105标准盖子,螺栓, 垫片,内置手柄

Design Specification for 2423-V-201 Item No. 1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Item Description 2423-V-201- Flare K.O. Drum Tag No.编号 Dry Hydrocarbons Content名称 ASME Sec.VIII Div.1 Applicable Code适用标准 mm 2000/6000 Inside Diameter/Length内径/长度 Operating Pressure工作压力 barg 0 / 0.25 (Min/Max) o C AMB Operating Temperature工作压力 External Design Pressure外部设计 barg F.V. 压力 Internal Design Pressure内部设计 barg 3.5 压力 Design Temperature (Min/Max)设 o C -0.418181818 计温度(最高/低) mm 1.5 Corrosion Allowance腐蚀裕度 Corrosion Allowance for Internals mm 0 内部组件内部件腐蚀裕度 Full/ E=1 Radiography /Joint Efficiency辐射/接口系数 No Post Weld Heat Treatment焊后热处理 Basic Wind Speed / T.O.G.Fact.基 36.12/ Exposure曝光 m/s ‘D’ 本风速/T.O.G.系数 UBC Zone 2B Earthquake地震强度 3 Kg/m No Lining/Density内衬/密度 Insulation Thickness / Type保温层 mm 30 / PP 厚度/种类 mm No Fire Proofing Thickness耐火厚度 3 Kg/m 580/612 Liquid Density(Min/Max)液体密度

(最小/大) 20 21 22 23 24 Capacity容积 Shop Test Pressure (Horizontal)车 间测试压力(水平) Lethal Service Ladder &Platform扶梯/平台 Code Stamping签章 m3 barg No Yes No 21 4.55

Construction Specification for 2423-V-201 Item 1 2
3 4

Description Shell壳体 Head封头 Fabrication Weight制造 重量 Erection Weight建筑重 量

Thickness 14 mm 10 mm
6670 Kg 10080 Kg

Item

Qty.

Size/Sch/Thk mm

Rating

Type

Service

Remark

N1 N2 N3 N4/N5 N6/N7 N8/N9 N10/N11 N12 N13 N14/N21 N15 N16 N17 N18/N19 N20

1 1 1 2 2 2 2 1 1 2 1 1 1 2 1

30”/-/12mm 24”/-/10mm 3”/80/3”/80/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/2”/160/ 2”/160/ -

150 150 150 300 300 300 300 300 300 150 150 150 300 300 150

W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F W.N.-R.F

Inlet入口 Gas Outlet出口气体出口 Liquid Outlet出口 LI(Trips) LI(Trips) LI(Trips) LI(Trips) Pressure Instrument压力 表 TI Utility Connection公用接 头 Vent出口 Drain排净口 TI(Trips) Level Bridle(Control)液位 计(控制) Electrical Heater电加热 器电加热器
With Blind带栅板 With Vortex Breaker带防涡器

M1

1

24”/-/10mm

150

W.N.-R.F

Manway走道

Finalized by Heater Vendor由供应 商敲定 Manway shall be supplied with cover, bolts, Gasket and internal hand grips acc. to STD.105走道应 配齐STD 105标准盖子,螺栓,垫片, 内置手柄

Design Specification for High Pressure Flare Drum Electrical Heater电加热器 Tag No.编号: 2323-H-101/201
Environmental Conditions环境条件: Power Rating额定功率 : 115 Kw Manufacturer Performance Requirements经营要求 Drum Content名称s Density密度 at P and Tkg/m Viscosity at T and P
3

Min / Max.Temp.: 2 / 48 oC

Humidity: 0.8

Altitude海拔: 70 m above sea level

Type :Immersion Heater电热煮沸器

Position : Inside Drum位置:锅筒内部

Electrical Requirements电力要求 Wet / Dry Hydrocarbons 580 / 1000 Hazardous Area Classification危险区分类 Inside Drum锅筒内 Outside Drum锅筒外 M.T IP Rating(JB) Insulation Class绝缘分类 Insulation Temp绝缘温度. Element Material (Wire / Sheath)材料元素成分 (线 材护套) Cable Gland Size Ni-Cr / Incoloy Zone 0, IIB,T3 Zone 2, IIB,T3

cp

0.31 / 1.6 131.6 / 44.2 0.094 AMB 20 200

Specific Heat / Molecular Weight 比热/分子重 量kj/kgmol.oC Thermal Conductivity w/K.m Temperature Minimum Start 最低起点 C Maximum Stop最高终止点 C Over Temp. Shut down o C Maximum Surface o C
o o

400V, 3Ph, 50 H IP56

Fouling Resistance 污垢热阻 m2.k/w Liquid Content名称s kg Time of raise Temperature Calculated heat Output kw Transfer rate: In service/ Clean Surface per Unit m2 Construction of Equipment Vessel Design Code容器设计标准

0.00035 min w/m . C
2 o

Control & Instruments Control Type: Power Controller Type: Heater Local Control Panel Temp. Sensor type:

Via Local Contro On / Off

Outdoor, Explosi Skin Type

Scope of Supply ASME Sec.VIII Div.1 13-Oct -0.496 -124 SS 316L SS 316L - /0 Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 Over Temp. Protection过热防护器 Bolting螺栓 Gasket垫片 Junction Box分线盒 Cabling(Between Local Control Panel本地控制柜 and Heater) CL.150, RF,WN Export Packing出口包装 Canopy顶盖 Skin Type Temp. Element &Transmitter温度传感 器 150 SS 316L Required Required Required Required Required Required Required Required Required Required

Design / Test Pressure设计/测试压力barg Design Temperature 设计温度oC MDMT 最低金属温度oC Material: Cover / End Plate材质:封头材料 Material: Element Sheath材料:护套 Corrosion Allowance腐蚀裕度: CS Part / SS Part mm Drum Nozzle Inside Diameter Drum Nozzle Flange Rating, ASME Class筒体 法兰接管等级:ASME类别 Weight kg Type of Cleaning Maintenance LLLS Height mm Internals内部组件 Material (Removable) Process Conditions:

Hydrocarbons shall contain H2S,CO2, mercaptans and water. Max. Molar % (Liquid Phase): H2S=9.4, CO2=6.6 and aromatic compounds may b lethal service.

Design Specification for Low Pressure Dry Flare Drum Electrical Heater电加热 器 Tag No.编号: 2323-H-102/202
Environmental Conditions环境条件: Power Rating额定功率 : 62 Kw Manufacturer Performance Requirements经营要求 Drum Content名称s Density密度 at P and T kg/m3 Viscosity 粘度 at T and P cp Specific Heat / Molecular Weight 比热/分子重 量kj/kgmol.oC Thermal Conductivity w/K.m Dry Hydrocarbons 545 / 620 0.14 / 0.23 177 / 73 0.098 Electrical Requirements电力要求 Hazardous Area Classification危险区分类 Inside Drum锅筒内 Outside Drum锅筒外 M.T IP Rating(JB) Zone 0, IIB,T3 Zone 2, IIB,T3 400V, 3Ph, 50 Hz IP56 Min / Max.Temp.: 2 / 48 oC Type :Immersion Heater电热煮沸器 Humidity: 0.8 Altitude海拔: 70 m above sea

Position : Inside Drum锅筒内位置:锅筒内部

Temperature Minimum Start 最低起点oC Maximum Stop最高终止点 C Over Temp. Shut down Maximum Surface o C Fouling Resistance 污垢热阻 m2.k/w Liquid Content名称s kg Time of raise Temperature Calculated heat Output Transfer rate: In service/ Clean Surface per Unit m2 Construction of Equipment Vessel Design Code容器设计标准 Design / Test Pressure设计/测试压力barg Design Temperature 设计温度oC MDMT 最高金属温度 C Material: Cover / End Plate材质:封头材料 Material: Element Sheath材料:护套 Corrosion Allowance腐蚀裕度: CS Part / SS Part mm Drum Nozzle Inside Diameter Drum Nozzle Flange Rating, ASME Class筒体 法兰接管等级:ASME类别 Weight kg Type of Cleaning Maintenance LLLS Height mm Internals内部组件 Material (Removable)
o o o

AMB 20 95 C

Insulation Class绝缘分类 Insulation Temp绝缘温度. Element Material (Wire / Sheath)材料元素成分 (线 材护套) Cable Gland Size

Ni-Cr / Incoloy

0.00017 min kw w/m 2.oC -

Control & Instruments Control Type: Power Controller Type: Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 type:

Via Local Control Pa 制柜 On / Off Skin Type

Outdoor, Explosion P

Scope of Supply ASME Sec.VIII Div.1 3.5 / 4.55 -0.85 -85 SS 316L SS 316L - /0 Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 Over Temp. Protection过热防护器 Bolting螺栓 Gasket垫片 Junction Box分线盒 Cabling(Between Local Control Panel本地控制柜 and Heater) CL.150, RF,WN Export Packing出口包装 Canopy顶盖 Skin Type Temp. Element &Transmitter温度传感 器 150 SS 316L Required Required Required Required Required Required Required Required Required Required

Process Conditions: C3-C9 dry hydrocarbons

Design Specification for Storage Flare Drum Electrical Heater电加热器电加热器 Tag No.编号: 2423-H-101
Environmental Conditions环境条件: Power Rating额定功率 : 46 Kw Min / Max.Temp.: 2 / 48 oC Humidity: 0.8 Altitude海拔: 70 m above sea level Type :Immersion Heater电热煮沸器 Position : Inside Drum锅筒内位置:锅筒内部

Manufacturer Performance Requirements经营要求 Drum Content名称s Density密度 at P and T kg/m3 Viscosity 粘度 at T and P cp Specific Heat / Molecular Weight 比热/分子重 量kj/kgmol.oC Thermal Conductivity w/K.m Temperature Minimum Start 最低起点 C Maximum Stop最高终止点 C Over Temp. Shut down o C Maximum Surface o C Fouling Resistance 污垢热阻 m2.k/w Liquid Content名称s kg Time of raise Temperature Calculated heat Output kw Transfer rate: In service/ Clean Surface per Unit m2 Construction of Equipment Vessel Design Code容器设计标准 Design / Test Pressure设计/测试压力barg Design Temperature 设计温度 C MDMT 最高金属温度oC Material: Cover / End Plate材质:封头材料 Material: Element Sheath材料:护套 Corrosion Allowance腐蚀裕度: CS Part / SS Part mm Drum Nozzle Inside Diameter Drum Nozzle Flange Rating, ASME Class筒体 法兰接管等级:ASME类别 Weight kg Type of Cleaning Maintenance LLLS Height mm Internals内部组件 Material (Removable) Process Conditions: C3-C9 dry hydrocarbons 150 SS 316L CL.150, RF,WN
o o o

Electrical Requirements电力要求 Dry Hydrocarbons 580 / 612 0.2 / 0.22 121.8 / 55.14 0.114 -20 20 105 Hazardous Area Classification危险区分类 Inside Drum锅筒内 Outside Drum锅筒外 M.T IP Rating(JB) Insulation Class绝缘分类 Insulation Temp绝缘温度. Element Material (Wire / Sheath)材料元素 成分(线材护套) Cable Gland Size Ni-Cr / Incoloy Zone 0, IIB,T3 Zone 2, IIB,T3 400V, 3Ph, 50 Hz IP56

0.00017 min w/m 2.oC

Control & Instruments Control Type: Power Controller Type: Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 type:

Via Local Control Panel本地 柜 On / Off

Outdoor, Explosion Proof, IP Skin Type

Scope of Supply ASME Sec.VIII Div.1 3.5 / 4.55 -0.4181818 -46 SA 516-60N SA 333-6 1.5 /0 Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 Over Temp. Protection过热防护器 Bolting螺栓 Gasket垫片 Junction Box分线盒 Cabling(Between Local Control Panel本地 控制柜 and Heater) Export Packing出口包装 Canopy顶盖 Skin Type Temp. Element &Transmitter温 度传感器 Required Required Required Required Required Required Required Required Required Required

Design Specification for Storage Flare Drum Electrical Heater电加热器电加热器

Tag No.编号: 2423-H-201
Environmental Conditions环境条件: Power Rating额定功率 : 46 Kw Manufacturer Performance Requirements经营要求 Drum Content名称s Density密度 at P and T kg/m3 Viscosity 粘度 at T and P cp Specific Heat / Molecular Weight 比热/分子重 量kj/kgmol.oC Thermal Conductivity w/K.m Temperature Minimum Start 最低起点 C Maximum Stop最高终止点 C Over Temp. Shut down Maximum Surface o C Fouling Resistance 污垢热阻 m2.k/w Liquid Content名称s kg Time of raise Temperature Calculated heat Output kw Transfer rate: In service/ Clean Surface per Unit m2 Construction of Equipment Vessel Design Code容器设计标准 Design / Test Pressure设计/测试压力barg Design Temperature 设计温度 C MDMT 最高金属温度 C Material: Cover / End Plate材质:封头材料 Material: Element Sheath材料:护套 Corrosion Allowance腐蚀裕度: CS Part / SS Part mm Drum Nozzle Inside Diameter Drum Nozzle Flange Rating, ASME Class筒体 法兰接管等级:ASME类别 Weight kg Type of Cleaning Maintenance LLLS Height mm Internals内部组件 Material (Removable) Process Conditions: C3-C9 dry hydrocarbons 150 SS 316L CL.150, RF,WN
o o o o o

Min / Max.Temp.: 2 / 48 oC Type :Immersion Heater电热煮沸器

Humidity: 0.8

Altitude海拔: 70 m above sea le

Position : Inside Drum锅筒内位置:锅筒内部

Electrical Requirements电力要求 Dry Hydrocarbons 580 / 612 0.2 / 0.22 121.8 / 55.14 0.114 -20 20 105 C Hazardous Area Classification危险区分类 Inside Drum锅筒内 Outside Drum锅筒外 M.T IP Rating(JB) Insulation Class绝缘分类 Insulation Temp绝缘温度. Element Material (Wire / Sheath)材料元素成分 (线 材护套) Cable Gland Size Ni-Cr / Incoloy Zone 0, IIB,T3 Zone 2, IIB,T3 400V, 3Ph, 50 Hz IP56

0.00017 min w/m . C
2 o

Control & Instruments Control Type: Power Controller Type: Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 type:

Via Local Control P 制柜 On / Off Outdoor, Explosion Skin Type

Scope of Supply ASME Sec.VIII Div.1 3.5 / 4.55 -0.418181818 -46 SA 516-60N SA 333-6 1.5 /0 Heater Local Control Panel本地控制柜 Temp. Sensor温度传感器 Over Temp. Protection过热防护器 Bolting螺栓 Gasket垫片 Junction Box分线盒 Cabling(Between Local Control Panel本地控制柜 and Heater) Export Packing出口包装 Canopy顶盖 Skin Type Temp. Element &Transmitter温度传感 器 Required Required Required Required Required Required Required Required Required Required


相关文章:
电加热器基本参数1
沧州市天龙燃烧设备有限公司 电加热器技术参数型号 DDR U F(25)-380/10-ex DDR U F(25)-380/10 DDR U F(25)-220/10 DDR U F(25)-380/20-ex DDR...
电加热器说明书
电加热器说明书_机械/仪表_工程科技_专业资料。空气电加热器 一、结构与功能 ...四、电气参数 1、产品的额定绝缘电压为 500 伏。 2、主电路额定工作电压为...
电加热器LU-906表参数设置(1)
电​加​热​器​L​U​-​9​0​6​表​参​数​设​置​( 暂无评价|0人阅读|0次下载|举报文档参数符号 LOC HAo LAo CooL ...
挂壁式石英电加热器参数
挂壁式石英电加热器参数_机械/仪表_工程科技_专业资料。选型资料挂壁式石英电加热器 挂壁式石英电加热器 详细介绍 ■ 石英电热器采用 PP 接线盒,PE 材质护套,加...
电加热器操作规程
报警表设定电加热器内部超温报警温度。然后观察控 制仪表、超温报警器观察正常后按工艺参数调节所需的温度; 4.3 控制柜面板控制:按一下电加热器的启动按钮,电...
电加热器使用说明书
制氮装置用隔爆兼增安型电加热器说明书 安装、使用产品前,请仔细阅读使用说明...1.3 基本参数产品型号 RJD-25/1140(660) 额定工作电 压(V) 1140/660 额定...
红外线电加热器和辐射式电加热器价格
防爆风道电加热器和车载电加热器参数 厂家:润联网 百度搜索润联网 百度搜索润联网 小型半导体风机加热器 1、紧凑型设计 2、无噪声 3、高 市场价格 效加热 4、...
红外线电加热器和辐射式电加热器价格
防爆风道电加热器和车载电加热器参数 厂家:润联网 百度搜索润联网 百度搜索润联网 小型半导体风机加热器 1、紧凑型设计 2、无噪声 3、高 市场价格 效加热 4、...
家用电加热器和管道加热器价格
信息来自润联网:http://wenku.runlian365.com 查看低价请登录"润联网" 家用电加热器和管道加热器价格标题:瓷套电加热器和防爆风道电加热器参数 厂家:润联网 ...
24v电加热器和管道加热器价格
辅助电加热器和蒸气电加热器价格 标题:BJW51A 温控器和导热油电加热器价格 库号: JX005858 价格:百度搜【润联网】查询 主要技术参数: 小型半导体风机加热器 1...
更多相关标签:
防爆电加热器zjlifan | 电加热器zjlifan | 电加热器 | 风管式电加热器 | 风管电加热器 | 风道电加热器 | 导热油电加热器 | 液体电加热器 |